{"title":"Autoclaves et accessoires pour dentistes","description":"","products":[{"product_id":"distillateur-deau-pour-autoclaves","title":"Water distiller for autoclaves","description":"\u003ch2\u003e Water distiller for autoclave\u003c\/h2\u003e\n\n\n\u003cp\u003e This water distiller is safe, reliable and easy to use. It has the capacity to produce 4 liters of water in approximately 4 hours (depending on the ambient temperature), which gives an average of 20 liters of water per day. Ideal for professional use in a podiatry practice.\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eTechnical specifications:\u003c\/strong\u003e\u003cbr\u003e\n • Has a replacement reusable filter.\u003cbr\u003e\n • Rated voltage: 220-240V - 50-60Hz\u003cbr\u003e\n • Nominal power: 700 W\u003cbr\u003e\n • Capacity: 4L\u003cbr\u003e\n • Distillation volume: 1L \/ hour\u003cbr\u003e\r \n• Overheat protection: turn off the device if the temperature reaches 160 ºC\u003cbr\u003e\n • \u003cstrong\u003e\u003cu\u003eThe filter should be changed every 2 months to ensure good water distillation\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDimensions (LxWxH): 23.5 x 22 x 38 cm\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"My Podologie","offers":[{"title":"Default Title","offer_id":49689017286975,"sku":"33.050","price":189.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67133.png?v=1725085407"},{"product_id":"autoclave-8-litres-classe-b-avec-usb","title":"8 Liter Class B Autoclave with USB","description":"\u003ch2\u003e White autoclave 8 liters class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\r \n- An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 170 x 320 mm\u003cbr\u003e\n - Tray size: 130 x 265 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 420 x 370 x 525 mm\u003cbr\u003e\n - Net weight: 37 kg\u003cbr\u003e\n - Maximum sound level: \u0026lt;70 dB\u003cbr\u003e\r \n- Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMaintaining your autoclave\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eThe error message guide\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\r \n- 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up. \u003cbr\u003e\n\u003cbr\u003e\n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e \u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49689048973631,"sku":"49.001","price":1990.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67078.png?v=1725085963"},{"product_id":"autoclave-12-litres-classe-b-avec-usb-rose","title":"Autoclave 12 Liters Class B with USB Pink","description":"\u003ch2\u003e 12 liter pink autoclave class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\r \n- Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 200 x 360 mm\u003cbr\u003e\n - Tray size: 156 x 295 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 420 x 370 x 595 mm\u003cbr\u003e\n - Net weight: 40 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\r \n- EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e \u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49689050415423,"sku":"49.002","price":2171.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67098.png?v=1725085991"},{"product_id":"autoclave-18-litres-classe-b-avec-usb","title":"18 Liter Class B Autoclave with USB","description":"\u003ch2\u003e White autoclave 18 liters class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\r \n- Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 247 x 350 mm\u003cbr\u003e\n - Tray size: 192 x 285 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 490 x 455 x 600 mm\u003cbr\u003e\n - Net weight: 47 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\r \n- EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e \u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49689050906943,"sku":"49.003","price":2405.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67085.png?v=1725086003"},{"product_id":"autoclave-kalipso-16l-carte-sd-by-eloi-podologie","title":"Autoclave KALIPSO 16L SD card by ELOI Podologie","description":"\u003cp\u003e \u003cstrong\u003e1- TRACEABILITY\u003c\/strong\u003e : Collection and archiving of data from sterilization cycles\u003cbr\u003e\n are managed by SD card. It is then easy to access the information\u003cbr\u003e\n to create a traceability file if necessary.\u003c\/p\u003e\n\n\n\u003cp\u003e\u003cbr\u003e \u003cstrong\u003e2- SIMPLICITY\u003c\/strong\u003e : A large screen allows you to view all the information\u003cbr\u003e\n necessary for the use of the machine. Cycle selection\u003cbr\u003e\n retained is simple and quick.\u003c\/p\u003e\n\n\n\u003cp\u003e\u003cbr\u003e \u003cstrong\u003e3- RELIABILITY\u003c\/strong\u003e : High-end and latest electronic components\u003cbr\u003e\n generation give Kalipso autoclaves exceptional reliability.\u003c\/p\u003e\n\n\n\u003cp\u003e\u003cbr\u003e \u003cstrong\u003e4- SAFETY\u003c\/strong\u003e : Mechanical and electromagnetic safety of the closure\u003cbr\u003e\n from the door.\u003cbr\u003e\n NIGHT CYCLE: The Kalispo power down all the\u003cbr\u003e\n functions of the appliance, one minute after the end of the cycle. Equipped with a process\u003cbr\u003e\n gradual cooling, no condensation is possible.\u003c\/p\u003e\n\n\n\u003cp\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003e16 L - SD\u003c\/strong\u003e\u003c\/p\u003e\n\n\n \u003cp\u003e\u003cstrong\u003eTECHNICAL CHARACTERISTICS\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e\u003cbr\u003e\n • Dimensions L x H x D: 528 x 400 x 638 mm\u003cbr\u003e\n • Sterilization chamber: Ø 245 x D 320 mm\u003cbr\u003e\n • Chamber material: AISI 304 stainless steel\u003cbr\u003e\n • Chamber payload: 5 kgs\u003cbr\u003e\n • Useful volume (l): 16\u003cbr\u003e\n • Door closing: Manual\u003cbr\u003e\n • Voltage \/ Frequency: 230V – 50\/60 HZ\u003cbr\u003e\n • Power: 1.4 kW\u003cbr\u003e\n • Sound level: \u0026lt; 70 dB\u003cbr\u003e\n • Weight: 57 kgs\u003cbr\u003e\n • Standard accessories: 1 tray support\u003cbr\u003e\n 1 tray handle\u003cbr\u003e\n • 4 aluminum trays: 184 x 17 x 286 mm\u003cbr\u003e\n • Type of cycles and total average duration\u003cbr\u003e\n 4 pre-established cycles\u003cbr\u003e\n \u0026gt; 121°C 60 min.\u003cbr\u003e\n \u0026gt; 134°C 47 min.\u003cbr\u003e\n \u0026gt; 134°C Flash 31 min.\u003cbr\u003e\n \u0026gt; 134°C Let's pray 62 min.\u003cbr\u003e\n • Total duration includes: vacuum, preheating, drying.\u003cbr\u003e\n Times are given for a fully loaded autoclave.\u003cbr\u003e\n Test Cycles\u003cbr\u003e\n \u0026gt; Vacuum test 18 min.\u003cbr\u003e\n \u0026gt; Helix B\u0026amp;D test 31 min.\u003c\/p\u003e\n\n","brand":"Eloi Podologie","offers":[{"title":"Default Title","offer_id":49689051758911,"sku":"20.021","price":5490.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67128.png?v=1725086031"},{"product_id":"autoclave-23-litres-classe-b-avec-usb","title":"23 Liter Class B Autoclave with USB","description":"\u003ch2\u003e White autoclave 23 liters class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\r \n- An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 247 x 450 mm\u003cbr\u003e\n - Tray size: 192 x 380 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2200W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 490 x 455 x 690 mm\u003cbr\u003e\n - Net weight: 53 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\r \n- Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\r \n- 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n4. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 5. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 6. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 7. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 9. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49689060671807,"sku":"49.004","price":2795.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67101.png?v=1725086237"},{"product_id":"autoclave-europa-b-pro-18-litres-tecno-gaz","title":"Europa B Pro autoclave 18 liters TechnoGaz","description":"\u003ch2\u003e Autoclave 18 liters Europa B Evo\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003cbr\u003e\n\u003cbr\u003e\n DESCRIPTION\u003c\/strong\u003e\u003cbr\u003e\r \nEuropa B Evo is part of the latest generation of autoclaves with multiple new features in terms of its aesthetics and operational efficiency.\u003cbr\u003e\n New navigation screen with blue display.\u003cbr\u003e\n Connection to the biological incubator controlled from the autoclave itself.\u003cbr\u003e\n New charging system positioned on the front of the autoclave.\u003cbr\u003e\n Europa B Evo is essential for all medical and dental facilities, as well as all sectors that require safe sterilization of all materials: hollow, porous, solid, bulk or packaged.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eFEATURES OF EUROPA B EVO:\u003c\/strong\u003e\u003cbr\u003e\n • Circular chamber in treated AISI 304 stainless steel.\u003cbr\u003e\n • Maximum load of 5 kg for each cycle.\u003cbr\u003e\n • 3 safety devices at the door: electromagnetic, electronic, dynamic.\u003cbr\u003e\n • Control card installed in the dashboard.\u003cbr\u003e\n • Graphical display.\u003cbr\u003e\n • Baric automatic alignment system.\u003cbr\u003e\r \n• Water filling system with pump and automatic blocking if tank is full.\u003cbr\u003e\n • Reinforcement of the door ensuring maximum durability.\u003cbr\u003e\n • Ability to automatically load or drain\u003cbr\u003e\n • Integrated ventilation system\u003cbr\u003e\n • Tray holder which prevents contact between the chamber and the load.\u003cbr\u003e\n • Built-in printer.\u003cbr\u003e\n • Biological incubator connector.\u003cbr\u003e\n • Manual closing\u003cbr\u003e\n • Pure demineralizer\u003cbr\u003e\n • Night cycle\u003cbr\u003e\n • PID system\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003ePID SYSTEM\u003c\/strong\u003e\u003cbr\u003e\n The commitment is to manufacture a product that provides solutions, that is functional, with unique characteristics that can guarantee the user the best reliability and great safety. Our research department with the support and collaboration of external organizations, has realized an extraordinary system that has been applied for the first time on our autoclaves. This innovative device is called PID\u003cbr\u003e\n\u003cbr\u003e\r \nPID stands for Proportional Integral Derivative, and is the highest expression of closed-loop controls. The structure of this sophisticated control is simple and flexible.PID\u003cbr\u003e\n Ensures the control and constant monitoring of the entire functional system of the autoclave, automatically intervening in the event of irregularities in the technical and electronic parameters. A device that acts as a \"technician proper\" capable of diagnosing and intervening in real time.\u003cbr\u003e\n\u003cbr\u003e\n A solution that reduces anomalies and alarms, guaranteeing the highest reliability and limiting machine downtime to a minimum.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTECHNICAL CHARACTERISTICS:\u003c\/strong\u003e\u003cbr\u003e\n • Height 395 mm\u003cbr\u003e\n • Width 510 mm\u003cbr\u003e\n • Depth 590 mm\u003cbr\u003e\n • Voltage 230 V \/ 50-60 Hz\u003cbr\u003e\n • 245 mm chamber diameter\u003cbr\u003e\n • Depth 320 mm camera\u003cbr\u003e\n • Weight 54 kg\u003cbr\u003e\n • Max. power: 1700 W\u003c\/p\u003e\n\n","brand":"Tecno-Gaz","offers":[{"title":"Default Title","offer_id":49689066275135,"sku":"42.003","price":6300.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67126.png?v=1725086353"},{"product_id":"autoclave-12-litres-classe-b-avec-usb","title":"12 Liter Class B Autoclave with USB","description":"\u003ch2\u003e White autoclave 12 liters class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\r \n- Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 200 x 360 mm\u003cbr\u003e\n - Tray size: 156 x 295 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 420 x 370 x 595 mm\u003cbr\u003e\n - Net weight: 40 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\r \n- EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e \u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49689535250751,"sku":"49.005","price":2171.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67117.png?v=1725094076"},{"product_id":"autoclave-18-litres-classe-b-avec-usb-vert","title":"Autoclave 18 Liters Class B with USB Green","description":"\u003ch2\u003e 18 liter green autoclave class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\r \n- Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 247 x 350 mm\u003cbr\u003e\n - Tray size: 192 x 285 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 490 x 455 x 600 mm\u003cbr\u003e\n - Net weight: 47 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\r \n- EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e \u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49689536266559,"sku":"49.006","price":2405.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67093.png?v=1725094108"},{"product_id":"autoclave-8-litres-classe-b-avec-usb-noir","title":"Autoclave 8 Liters Class B with USB Black","description":"\u003ch2\u003e Black autoclave 8 liters class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\r \n- Low water alarm indicates when the water tank is empty or too full.\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 170 x 320 mm\u003cbr\u003e\n - Tray size: 130 x 265 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 420 x 370 x 525 mm\u003cbr\u003e\n - Net weight: 37 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\r \n- EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e \u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49689544163647,"sku":"49.007","price":1990.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67123.png?v=1725094236"},{"product_id":"autoclave-12-litres-classe-b-avec-usb-noir","title":"Autoclave 12 Liters Class B with USB Black","description":"\u003ch2\u003e Black autoclave 12 liters class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\r \n- Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 200 x 360 mm\u003cbr\u003e\n - Tray size: 156 x 295 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 420 x 370 x 595 mm\u003cbr\u003e\n - Net weight: 40 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\r \n- EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e \u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49689544622399,"sku":"49.008","price":2171.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67095.png?v=1725094250"},{"product_id":"filtre-bacteriologique-de-rechange-pour-autoclave","title":"Replacement Bacteriological Filter for Autoclave","description":"\u003cp\u003e Bacteriology filter for class B autoclave\u003c\/p\u003e\n\n","brand":"My Podologie","offers":[{"title":"Default Title","offer_id":49689682968895,"sku":"33.412","price":35.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/53182_758d30cb-bd34-4d15-b115-688f69fb6196.jpg?v=1725096720"},{"product_id":"filtre-interne-de-rechange-pour-autoclave","title":"Replacement Internal Filter for Autoclave","description":"\u003cp\u003e Replacement Internal Filter for Autoclave\u003c\/p\u003e\n\n","brand":"My Podologie","offers":[{"title":"Default Title","offer_id":49689683263807,"sku":"33.413","price":20.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/5476_49931d49-a9e9-428d-a617-6656437d4994.jpg?v=1725096728"},{"product_id":"autoclave-kalipso-22l-carte-sd-by-eloi-podologie","title":"Autoclave KALIPSO 22L SD card by ELOI Podologie","description":"\u003cp\u003e \u003cstrong\u003e1- TRACEABILITY\u003c\/strong\u003e : Collection and archiving of data from sterilization cycles\u003cbr\u003e\n are managed by SD card. It is then easy to access the information\u003cbr\u003e\n to create a traceability file if necessary.\u003c\/p\u003e\n\n\n\u003cp\u003e\u003cbr\u003e \u003cstrong\u003e2- SIMPLICITY\u003c\/strong\u003e : A large screen allows you to view all the information\u003cbr\u003e\n necessary for the use of the machine. Cycle selection\u003cbr\u003e\n retained is simple and quick.\u003c\/p\u003e\n\n\n\u003cp\u003e\u003cbr\u003e \u003cstrong\u003e3- RELIABILITY\u003c\/strong\u003e : High-end and latest electronic components\u003cbr\u003e \ngeneration give Kalipso autoclaves exceptional reliability.\u003c\/p\u003e\n\n\n\u003cp\u003e\u003cbr\u003e \u003cstrong\u003e4- SAFETY\u003c\/strong\u003e : Mechanical and electromagnetic safety of the closure\u003cbr\u003e\n from the door.\u003cbr\u003e\n NIGHT CYCLE: The Kalispo power down all the\u003cbr\u003e\n functions of the appliance, one minute after the end of the cycle. Equipped with a process\u003cbr\u003e\n gradual cooling, no condensation is possible.\u003c\/p\u003e\n\n\n\u003cp\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003e22 L - SD\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eTECHNICAL CHARACTERISTICS\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e\u003cbr\u003e\n • Dimensions L x H x D: 510 x 400 x 730 mm\u003cbr\u003e\n • Sterilization chamber: Ø 245 x D 500 mm\u003cbr\u003e\n • Chamber material: AISI 304 stainless steel\u003cbr\u003e\n • Chamber payload: 7 kgs\u003cbr\u003e\n • Useful volume (l): 22\u003cbr\u003e\n • Door closing: Manual\u003cbr\u003e\n • Voltage \/ Frequency: 230V – 50\/60 HZ\u003cbr\u003e\n • Power: 2.1 kW\u003cbr\u003e\n • Sound level: \u0026lt; 70 dB\u003cbr\u003e\n • Weight: 57 kgs\u003cbr\u003e\n • Standard accessories: 1 tray support\u003cbr\u003e\n 1 tray handle\u003cbr\u003e\n • 4 aluminum trays: 184 x 17 x 426 mm\u003cbr\u003e\n • Type of cycles and total average duration\u003cbr\u003e\n 4 pre-established cycles\u003cbr\u003e\n \u0026gt; 121°C 60 min.\u003cbr\u003e \n\u0026gt; 134°C 47 min.\u003cbr\u003e\n \u0026gt; 134°C Flash 31 min.\u003cbr\u003e\n \u0026gt; 134°C Let's pray 62 min.\u003cbr\u003e\n • Total duration includes: vacuum, preheating, drying.\u003cbr\u003e\n Times are given for a fully loaded autoclave.\u003cbr\u003e\n Test Cycles\u003cbr\u003e\n \u0026gt; Vacuum test 18 min.\u003cbr\u003e\n \u0026gt; Helix B\u0026amp;D test 31 min.\u003c\/p\u003e\n\n","brand":"Eloi Podologie","offers":[{"title":"Default Title","offer_id":49690111410495,"sku":"20.102","price":5560.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67131.png?v=1725111330"},{"product_id":"joint-de-porte-pour-autoclave-icanclave","title":"Door seal for Icanclave autoclave","description":"\u003cp\u003e Please note that depending on arrivals, the color of the seal may change.\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"8 L","offer_id":49690128777535,"sku":"49.009.01","price":61.5,"currency_code":"EUR","in_stock":true},{"title":"12 L","offer_id":49690128810303,"sku":"49.009.02","price":68.5,"currency_code":"EUR","in_stock":true},{"title":"18 L \u0026amp; 23 L","offer_id":49690128843071,"sku":"49.009.03","price":71.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/83535.png?v=1725111866"},{"product_id":"cle-du-reglage-de-la-porte-pour-autoclave-my-podologie","title":"Autoclave Door Adjustment Key - My Podologie","description":"\u003ch2\u003e Autoclave door adjustment key\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eGeneral characteristics:\u003c\/strong\u003e\u003cbr\u003e\r \n• Ideal for properly adjusting the Icanclave autoclave door\u003c\/p\u003e\n\n","brand":"My Podologie","offers":[{"title":"Default Title","offer_id":49690829357375,"sku":"33.1020","price":29.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/83806.png?v=1725134398"},{"product_id":"autoclave-enbio-s-2-7-litres","title":"Enbio S autoclave - 2.7 liters","description":"\u003ch2\u003eAutoclave Enbio S - 2.7 litres Classe B ultra rapide pour la stérilisation des instruments chirurgicaux\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 159, 148);\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(54, 169, 225);\"\u003e\u003ca rel=\"noopener\" style=\"color: rgb(54, 169, 225);\" title=\"Garantie Autoclave Enbio\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/GARANTIES_AUTOCLAVES_ENBIO_1_site_1.png?v=1775724000\" target=\"_blank\"\u003eGarantie Autoclave Enbio\u003c\/a\u003e \u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"color: rgb(54, 169, 225);\"\u003e\u003ca style=\"color: rgb(54, 169, 225);\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/2317\/8823\/files\/Manuel_d_utilisation_Enbio_Pro_et_S.pdf?v=1719930861\" title=\"Manuel d'utilisation Pro\" rel=\"noopener\" target=\"_blank\"\u003eManuel d'utilisation Enbio \u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left; margin: 20px 0;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/videos\/c\/o\/v\/b0f56f0017a64f1c842ba2e2e0a410bf.mp4\" style=\"display: inline-block; padding: 10px 20px; background-color: #003959; color: #fff; text-decoration: none; border-radius: 5px; font-family: Arial, sans-serif; font-size: 16px; transition: background-color 0.3s ease;\" target=\"_blank\"\u003eINSTALLATION EN VIDÉO\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left; margin: 20px 0;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/2317\/8823\/files\/Maintenance_Enbio_S_Enbio_Pro.pdf?v=1753342777\" style=\"display: inline-block; padding: 10px 20px; background-color: #003959; color: #fff; text-decoration: none; border-radius: 5px; font-family: Arial, sans-serif; font-size: 16px; transition: background-color 0.3s ease;\" target=\"_blank\"\u003eMAINTENANCE\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left; margin: 20px 0;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/2317\/8823\/files\/Nettoyage_du_generateur_de_vapeur_Enbio.pdf?v=1753342900\" style=\"display: inline-block; padding: 10px 20px; background-color: #003959; color: #fff; text-decoration: none; border-radius: 5px; font-family: Arial, sans-serif; font-size: 16px; transition: background-color 0.3s ease;\" target=\"_blank\"\u003eNETTOYAGE GÉNÉRATEUR DE VAPEUR\u003c\/a\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003eEnbio S est un \u003cmeta charset=\"utf-8\"\u003estérilisateur simple d'utilisation, compact et facile à installer. \u003cbr\u003e\u003cbr\u003eLes autoclaves ENBIO sont jusqu’à 6 fois plus petits et jusqu’à 3 fois plus légers que les autoclaves typiques de classe B, étant, en même temps, également efficaces que ceux-ci.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCaractéristiques : \u003c\/strong\u003e\u003cbr\u003e• Classe B\u003cbr\u003e• Cycle rapide\u003cbr\u003e• \u003cmeta charset=\"utf-8\"\u003eCapacité de 2,7 litres : peut contenir jusqu'à 8 sachets de stérilisation ou les instruments directement en vrac\u003cbr\u003e• \u003cspan\u003e Format compact (25 x 16 x 56 cm)\u003c\/span\u003e\u003cbr\u003e• Silencieux : 40 dB. Vous pouvez stériliser vos instruments tout en recevant vos patients dans votre cabinet sans même qu'ils ne remarquent qu'il fonctionne\u003cbr\u003e• Approvisionnement en eau : l'autoclave Enbio S utilise de \u003cstrong\u003el'eau distillée\u003c\/strong\u003e provenant d'un réservoir externe\u003cbr\u003e• Alimentation électrique : fonctionne avec n'importe quelle prise électrique classique\u003cbr\u003e• Archivage des données : toutes les données du processus sont automatiquement enregistrées sur une clé USB, plus besoin de les enregistrer manuellement\u003cbr\u003e• Rapports de processus : logiciel dédié à la lecture et à l'impression des données du processus\u003cbr\u003e• Dimensions plateau intérieur : \u003cmeta charset=\"utf-8\"\u003e28 x 18 x 3,5 cm\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e• Garantie : 2 ans  \u003cbr\u003e• Fabrication Suisse\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e3 programmes de stérilisation : \u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width: 500px; height: 161px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 93.375px;\"\u003eProgramme\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 85.4219px;\"\u003e134°C FAST\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 103.016px;\"\u003e134°C\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 103.016px;\"\u003e121°C\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 87.1719px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"height: 55.1875px; width: 93.375px;\"\u003e\n\u003cp\u003eDurée total de la stérilisation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 55.1875px; width: 85.4219px;\"\u003e10 min\u003c\/td\u003e\n\u003ctd style=\"height: 55.1875px; width: 103.016px;\"\u003e18 min\u003c\/td\u003e\n\u003ctd style=\"height: 55.1875px; width: 103.016px;\"\u003e30 min\u003c\/td\u003e\n\u003ctd style=\"height: 55.1875px; width: 87.1719px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"height: 58.7812px; width: 93.375px;\"\u003eType de charge\u003c\/td\u003e\n\u003ctd style=\"height: 58.7812px; width: 85.4219px;\"\u003eInstruments en vrac\u003c\/td\u003e\n\u003ctd style=\"height: 58.7812px; width: 103.016px;\"\u003eInstruments emballés\/ non emballés\u003c\/td\u003e\n\u003ctd style=\"height: 58.7812px; width: 103.016px;\"\u003eInstruments emballés\/ non emballés\u003c\/td\u003e\n\u003ctd style=\"height: 58.7812px; width: 87.1719px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cp\u003eContrairement à l'Enbio Pro, \u003cspan\u003e \u003c\/span\u003el'Enbio S n'effectue pas le cycle PRION\u003c\/p\u003e","brand":"Enbio","offers":[{"title":"White","offer_id":49690833813823,"sku":"271.001.01","price":2100.0,"currency_code":"EUR","in_stock":true},{"title":"Black Edition","offer_id":49690833977663,"sku":"271.001.06","price":2100.0,"currency_code":"EUR","in_stock":true},{"title":"Gray","offer_id":49690833846591,"sku":"271.001.02","price":2100.0,"currency_code":"EUR","in_stock":false},{"title":"Blue","offer_id":49690833879359,"sku":"271.001.03","price":2100.0,"currency_code":"EUR","in_stock":false},{"title":"YELLOW","offer_id":49690833912127,"sku":"271.001.04","price":2100.0,"currency_code":"EUR","in_stock":false},{"title":"Pink","offer_id":49690833944895,"sku":"271.001.05","price":2100.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/75056_a20e2ce0-978a-47fe-afac-0c214a1c8068.jpg?v=1725134439"},{"product_id":"autoclave-enbio-pro-5-3-litres","title":"Enbio Pro autoclave - 5.3 liters","description":"\u003ch2\u003e Enbio Pro Ultra Fast Class B Autoclave for Sterilization of Surgical Instruments\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n Enbio Pro is a simple to use, compact and easy to install autoclave.\n\u003cbr\u003e\u003cbr\u003e\r \nENBIO autoclaves are up to 6 times smaller and up to 3 times lighter than typical Class B autoclaves, while being equally efficient.\u003cbr\u003e\n\u003cbr\u003e\n\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003eInstallation of the Enbio autoclave\u003c\/strong\u003e \u003c\/p\u003e\n\n\u003ciframe width=\"600\" height=\"300\" src=\"https:\/\/www.youtube.com\/embed\/bhUKZS8zueI\" title=\"How to install the Enbio Autoclave\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\n\u003cbr\u003e\u003cbr\u003e\n \u003cstrong\u003eFeatures :\u003c\/strong\u003e\u003cbr\u003e\n • Class B\u003cbr\u003e\n • Fast cycle\u003cbr\u003e\n • 5.3 litre capacity: can hold up to 16 sterilisation pouches or instruments directly in bulk\u003cbr\u003e\n • External dimensions: L 56 x W 27 x H 20 cm\u003cbr\u003e\n • Quiet: 40 dB. You can sterilize your instruments while receiving your patients in your office without them even noticing that it is working\u003cbr\u003e\n • Water supply: the Enbio Pro autoclave uses \u003cstrong\u003edistilled water\u003c\/strong\u003e from an external tank\u003cbr\u003e\n • Power supply: works with any standard electrical outlet\u003cbr\u003e\r \n• Data archiving: all process data is automatically saved to a USB stick, no need to save it manually\u003cbr\u003e\n • Process reports: software dedicated to reading and printing process data\u003cbr\u003e\n • 3 trays included\u003cbr\u003e\n • Interior tray dimensions: 28 x 18 x 7 cm\u003cbr\u003e\n • Warranty: 2 years (excluding servicing)\u003cbr\u003e\n • Swiss manufacturing\n\n\u003cp style=\"text-align:center;\"\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/100-tout-savoir-sur-les-autoclaves-enbio\" rel=\"noreferrer noopener\" target=\"_blank\"\u003eLEARN MORE ABOUT CUSTOMER SERVICE\u003c\/a\u003e\u003c\/p\u003e\n\n\n\u003cp style=\"text-align:center;\"\u003e \u003cstrong\u003e4 sterilization programs:\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:500px;\"\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e Program\u003c\/td\u003e\n\n\u003ctd\u003e 134°C FAST\u003c\/td\u003e\n\n\u003ctd\u003e 134°C\u003c\/td\u003e\n\n\u003ctd\u003e 121°C\u003c\/td\u003e\n\n\u003ctd\u003e 134°C PRION\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\n\n\u003cp\u003e Total duration of sterilization\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\u003ctd\u003e 10 min\u003c\/td\u003e\n\n\u003ctd\u003e 18 min\u003c\/td\u003e\n\n\u003ctd\u003e 30 min\u003c\/td\u003e\n\n\u003ctd\u003e 43min\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e Type of charge\u003c\/td\u003e\n\n\u003ctd\u003e Bulk instruments\u003c\/td\u003e\n\n\u003ctd\u003e Packaged\/Unpackaged Instruments\u003c\/td\u003e\n\n\u003ctd\u003e Packaged\/Unpackaged Instruments\u003c\/td\u003e\n\n\u003ctd\u003e Packaged instruments\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e Drying\u003c\/td\u003e\n\n\u003ctd\u003e -\u003c\/td\u003e\n\n\u003ctd\u003e Yes\u003c\/td\u003e\n\n\u003ctd\u003e Yes\u003c\/td\u003e\n\n\u003ctd\u003e Yes\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e Class\u003c\/td\u003e\n\n\u003ctd\u003e S\u003c\/td\u003e\n\n\u003ctd\u003e B\u003c\/td\u003e\n\n\u003ctd\u003e B\u003c\/td\u003e\r \n\u003ctd\u003eB - PRION\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\n\n\u003cp\u003e\u003cbr\u003e\n \u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n • Power: 230V\/50Hz\u003cbr\u003e\n • Installed power: 3250 W\u003cbr\u003e\n • Maximum power consumption: 15 A\u003cbr\u003e\n • Working pressure: 2.1 Bar\u003cbr\u003e\n • Maximum pressure: 2.3 Bar\u003cbr\u003e\n • Maximum process temperature: 138°C\u003cbr\u003e\n • Sterilization volume: 5.3 l\u003cbr\u003e\n • Approximate maximum number of packs: 16\u003cbr\u003e\n • Maximum load weight: 0.8 kg\u003cbr\u003e\n • Weight: 20 kg\u003cbr\u003e\n • Degree of protection: IP20\u003cbr\u003e\n • Process data storage: USB stick\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAdditional accessory - The Enbio magic filter:\u003c\/strong\u003e\u003cbr\u003e\n The magic filter allows the autoclave to reuse waste water during sterilization processes. By using this filter you will no longer have to worry about constantly replacing the bottle of demineralized or distilled water. The magic filter will allow you to save 400L of water, or 80 5L cans.\u003cbr\u003e\r \nIt is a product designed to reduce the amount of waste, water consumption and to respect the environment. Accessory not included in the purchase of the autoclave.\u003c\/p\u003e\n\n\n\u003cp style=\"text-align:center;\"\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/55033-filtre-magic-pour-enbio-s-et-enbio-pro-1811166874782.html\" rel=\"noreferrer noopener\" target=\"_blank\"\u003eVIEW PRODUCT\u003c\/a\u003e\u003c\/p\u003e\n\n\n\u003cp style=\"text-align:center;\"\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eIt is important to keep the packaging box in case of after-sales service.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Enbio","offers":[{"title":"Default Title","offer_id":49690838499647,"sku":"271.002","price":2490.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/64214.png?v=1725134503"},{"product_id":"filtre-hepa-pour-enbio-s-et-enbio-pro","title":"HEPA filter for Enbio S and Enbio Pro","description":"\u003cp\u003eReplacement HEPA filter for Enbio S and Enbio Pro autoclave\u003c\/p\u003e\n","brand":"Enbio","offers":[{"title":"Default Title","offer_id":49690971865407,"sku":"271.003","price":39.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/64195.png?v=1725138761"},{"product_id":"front-set-pour-enbio-pro","title":"Front Set for Enbio Pro","description":"\u003cp\u003eReplacement front assembly for the Enbio Pro autoclave.\u003c\/p\u003e\n","brand":"Enbio","offers":[{"title":"Default Title","offer_id":49690972062015,"sku":"271.004","price":180.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67141_5cb5b842-90e9-464c-9130-ce2fa6ed0722.jpg?v=1725138772"},{"product_id":"kit-de-3-plateaux-pour-enbio-pro","title":"3 Tray Kit for Enbio Pro","description":"\u003cp\u003eExternal dimensions:\u003c\/p\u003e\n\n\u003cp\u003e tray - 291x190x70 mm\u003c\/p\u003e\n\n\u003cp\u003e Perforated insert from below: 278x177x6 mm\u003c\/p\u003e\n\n\u003cp\u003e Perforated upper insert: 200x189x18 mm\u003c\/p\u003e\n","brand":"Enbio","offers":[{"title":"Default Title","offer_id":49690972127551,"sku":"271.005","price":208.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/75063.png?v=1725138777"},{"product_id":"tuyau-sortie-deau-pour-enbio-s-et-enbio-pro","title":"Water outlet pipe for Enbio S and Enbio Pro","description":"\u003ch2\u003eReplacement water outlet hose - Enbio S and Pro autoclave\u003c\/h2\u003e\n\n\u003cp\u003e Replacement hose for water outlet of Enbio S and Pro autoclave.\u003c\/p\u003e\n\n\u003cp\u003e 1.50m hose + cap\u003c\/p\u003e\n","brand":"Enbio","offers":[{"title":"Default Title","offer_id":49690972225855,"sku":"271.006","price":36.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67074.png?v=1725138785"},{"product_id":"tuyau-entree-deau-pour-enbio-s-et-enbio-pro","title":"Water inlet pipe for Enbio S and Enbio Pro","description":"\u003ch2\u003eReplacement water inlet hose - Enbio S and Pro autoclave\u003c\/h2\u003e\n\n\u003cp\u003e 1.50m hose + a plug\u003c\/p\u003e\n","brand":"Enbio","offers":[{"title":"Default Title","offer_id":49690972324159,"sku":"271.007","price":36.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67072.png?v=1725138794"},{"product_id":"filtre-magic-pour-enbio-s-et-enbio-pro","title":"Magic Filter for Enbio S and Enbio Pro","description":"\u003cp\u003eEnbio Magic Filter is a product that will change the way you perform sterilization. Thanks to its innovative technology, based on ion exchange resin, it allows the reuse of wastewater during sterilization processes. Magic Filter was created with the idea of protecting the environment and reducing the amount of waste. By using this filter, you will no longer have to worry about constantly replacing the bottle with demineralized or distilled water. It is a product that respects your time and money, while being more respectful of the environment.\u003c\/p\u003e\n\n\u003cp\u003e Capacity: 400L-500L\u003c\/p\u003e\n","brand":"Enbio","offers":[{"title":"Default Title","offer_id":49690972455231,"sku":"271.008","price":50.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67076.png?v=1725138803"},{"product_id":"cle-usb-memoire-de-16gb-pour-enbio-s-et-enbio-pro","title":"16GB USB memory stick for Enbio S and Enbio Pro","description":"\u003cp\u003eCapacity: 16GB\u003c\/p\u003e\n\n\u003cp\u003e Suitable for: Enbio S and Enbio Pro autoclaves\u003c\/p\u003e\n","brand":"Enbio","offers":[{"title":"Default Title","offer_id":49690972651839,"sku":"271.009","price":34.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67132.png?v=1725138815"},{"product_id":"front-set-pour-enbio-s","title":"Front Set for Enbio S","description":"\u003cp\u003eSuitable for: Enbio S autoclave\u003c\/p\u003e\n","brand":"Enbio","offers":[{"title":"Default Title","offer_id":49690972717375,"sku":"271.010","price":148.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67140.png?v=1725138820"},{"product_id":"plateau-pour-enbio-s","title":"Tray for Enbio S","description":"\u003ch2\u003eSterilization tray for the Enbio S autoclave\u003c\/h2\u003e\n\n\u003cp\u003e\u003cbr\u003e\n Perforated base\u003cbr\u003e\n Dimensions: 288 x 183 x 31 mm\u003cbr\u003e\n High quality and heat resistant\u003c\/p\u003e\n","brand":"Enbio","offers":[{"title":"Default Title","offer_id":49690972815679,"sku":"271.011","price":68.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/73277_2ee3baf7-680b-4fe1-806f-0130bd7fc50c.jpg?v=1725138824"},{"product_id":"porte-pinces-hydrim-c61-ruck","title":"Pliers holder - HYDRIM C61 - Ruck","description":"\u003cp\u003e Secure attachment in the base basket\u003c\/p\u003e\n\n\n\u003cp\u003e You can store up to 7 pliers on this stainless steel holder. The space is used optimally.\u003c\/p\u003e\n\n","brand":"Ruck","offers":[{"title":"Default Title","offer_id":49690988314943,"sku":"47.1328","price":149.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67225.png?v=1725139271"},{"product_id":"autoclave-blanc-8-litres-classe-b-avec-usb-et-imprimante-integree","title":"White Autoclave 8 Liters Class B with USB and integrated printer","description":"\u003ch2\u003e 8 litre white autoclave class B with USB and integrated printer\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\r \n- Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - External dimensions of the device: W x H x L: 420 x 370 x 525 mm\u003cbr\u003e\n - Tray dimensions: 265 x 130 mm\u003cbr\u003e\r \n- Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - 1750W\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - Net weight: 37 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\r \n- Internal printer (allows printing of sterilization cycle reports on thermal paper after the end of the cycle.)\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\r \n1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Plug in the printer.\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\n 5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\r \n6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\n After selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\r \nOnce the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49691004502335,"sku":"49.014","price":1990.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/Autoclave-Blanc-8-Litres-Classe-B-avec-USB-et-imprimante-integree-Icanclave-Autoclaves-219977234.webp?v=1751882679"},{"product_id":"autoclave-blanc-12-litres-classe-b-avec-usb-et-imprimante-integree","title":"White autoclave 12 Liters Class B with USB and integrated printer","description":"\u003ch2\u003e 12 litre white autoclave class B with USB and integrated printer\u003c\/h2\u003e\n\n\n \u003cp\u003e\u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\r \n- Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - External dimensions of the device: W x H x L: 420 x 370 x 595 mm\u003cbr\u003e\n - Tray dimensions: 315 x 160 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - 1750W\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - Net weight: 40 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\r \n- Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Internal printer (allows printing of sterilization cycle reports on thermal paper after the cycle is complete.)\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 3 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\r \n\u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Plug in the printer.\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\n 5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\r \n6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\n After selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\r \nOnce the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49691004600639,"sku":"49.015","price":2171.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/Autoclave-blanc-12-Litres-Classe-B-avec-USB-et-imprimante-integree-Icanclave-Autoclaves-219976979.webp?v=1760090700"},{"product_id":"autoclave-blanc-18-litres-classe-b-avec-usb-et-imprimante-integree","title":"White Autoclave 18 Liters Class B with USB and integrated printer","description":"\u003ch2\u003e 18 litre white autoclave class B with USB and integrated printer\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured. \u003cbr\u003e\n- Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - External dimensions of the device: W x H x L: 490 x 455 x 600 mm\u003cbr\u003e\n - Tray dimensions: 285 x 192 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - 1750W\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - Net weight: 47 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Internal printer (allows printing of sterilization cycle reports on thermal paper after the cycle is complete.)\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 3 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\r \n- 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Plug in the printer.\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49691004797247,"sku":"49.016","price":2405.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/87110.png?v=1725140475"},{"product_id":"autoclave-blanc-23-litres-classe-b-avec-usb-et-imprimante-integree","title":"White autoclave 23 Liters Class B with USB and integrated printer","description":"\u003ch2\u003e 23 litre white autoclave class B with USB and integrated printer\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured. \u003cbr\u003e\n- Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - External dimensions of the device: W x H x L: 490 x 455 x 690 mm\u003cbr\u003e\n - Tray dimensions: 380 x 192 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - 1750W\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - Net weight: 53 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Internal printer (allows printing of sterilization cycle reports on thermal paper after the cycle is complete.)\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 3 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\r \n- 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Plug in the printer.\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49691004862783,"sku":"49.017","price":2795.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/87113.png?v=1725140487"},{"product_id":"autoclave-blanc-29-litres-classe-b-avec-usb-et-imprimante-integree","title":"White autoclave 29 liters Class B with USB and integrated printer","description":"\u003ch2\u003e 29 litre white autoclave class B with USB and integrated printer\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\r \n- Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - External dimensions of the device: W x H x L: 490 x 455 x 860 mm\u003cbr\u003e\n - Tray dimensions: 380 x 192 mm\u003cbr\u003e\r \n- Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - 2300W\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - Net weight: 65 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\r \n- Internal printer (allows printing of sterilization cycle reports on thermal paper after the cycle is complete.)\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 3 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\r \n1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Plug in the printer.\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\n 5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\r \n6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\n After selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\r \nOnce the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49691005911359,"sku":"49.018","price":4420.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/69690.png?v=1725140608"},{"product_id":"multisteril-fast-dispositif-automatique-pour-desinfection-ultrasons-et-sechage","title":"Multisteril Fast - Automatic device for disinfection, ultrasound and drying","description":"\u003ch2\u003e Multisteril Fast - Automatic device for disinfection, ultrasound and drying with pump\u003c\/h2\u003e\n\n\n \u003cp\u003eFor many years, Techno-Gaz has revolutionized the sterilization process procedures by inventing the MultiSteril multifunction system.\u003cbr\u003e\n\u003cbr\u003e\n With the invention of MultiSteril, the brand has demonstrated its ability to know and interpret a sector in which it has been a leader for many years. Now discover MultiSteril Fast, the evolution of a system that has revolutionized and simplified a protocol that we have taken from manual to completely automated.\u003cbr\u003e\n\u003cbr\u003e\n The MultiSteril Fast evolves thanks to the application of new technologies that guarantee a reduction in treatment times (static disinfection, ultrasonic cleaning, rinsing, drying) by half, to reach a time of only about 20 minutes.\u003cbr\u003e\n\u003cbr\u003e\n A unique device, essential in all structures practicing sterilization.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003e\u003cspan style=\"font-size:16px;\"\u003eAbility :\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\r \n9 litre tank with the capacity to process up to 5kg of instruments equivalent to the load of an 18 to 20 litre autoclave.\u003cbr\u003e\n\u003cbr\u003e\n \u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n • \u003cstrong\u003eHeating\u003c\/strong\u003e\u003cbr\u003e\n The device performs heating and initial static decontamination of the instruments.\u003cbr\u003e\n\u003cbr\u003e\n • \u003cstrong\u003eDegassing\u003c\/strong\u003e\u003cbr\u003e\n This process removes dissolved gases from the water to avoid interference with the ultrasound and improve process efficiency.\u003cbr\u003e\n\u003cbr\u003e\n • \u003cb\u003eUltrasonic cleaning\u003c\/b\u003e\u003cbr\u003e\n Once degassing is complete, ultrasonic cleaning begins by causing cavitation which eliminates chemical and organic residues from the material immersed in the tank and thus eliminates the bacterial load by more than 95%. The duration of this procedure can be programmed by the operator between 5 and 30 minutes.\u003cbr\u003e\n\u003cbr\u003e\n • \u003cstrong\u003eEvacuation\u003c\/strong\u003e\u003cbr\u003e\n Once cleaning is complete, Multisteril automatically empties all liquids contained in the tank.\u003cbr\u003e\n\u003cbr\u003e\r \n• \u003cb\u003eRinsing\u003c\/b\u003e\u003cbr\u003e\n In order to remove any chemical residue from the instruments, the device rinses by injecting pressurized water through the nozzles located in the cover. The injected water is then automatically drained.\u003cbr\u003e\n\u003cbr\u003e\n • \u003cb\u003eDrying\u003c\/b\u003e\u003cbr\u003e\n To dry the materials, the machine sends a jet of hot water produced by a fan and a resistor located on the cover of the device which eliminates the humidity in the form of steam.\u003cbr\u003e\n\u003cbr\u003e\n \u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eBenefits :\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n • \u003cstrong\u003eExtraordinary speed\u003c\/strong\u003e\u003cbr\u003e\n The MultiSteril Fast revolutionizes the role of the operator in charge of the sterilization cycle, who only has to insert and remove the instruments in the tank. There is no operational responsibility, no risk, the process is automatic and controlled. No direct role of the operator, therefore significant time saving, which he can use for other activities.\u003cbr\u003e\n\u003cbr\u003e\r \n• \u003cstrong\u003eBetter rotation and availability of instruments and greater working flexibility\u003c\/strong\u003e\u003cbr\u003e\n You will avoid purchasing new instruments to compensate for the lack of availability caused by long processing times (as happens with all other devices).\u003cbr\u003e\n\u003cbr\u003e\n • \u003cstrong\u003eNo human intervention\u003c\/strong\u003e\u003cbr\u003e\n All phases of disinfection, cleaning, rinsing and drying are automated without any human intervention, this allows to fully satisfy the protocols and avoid errors and negligence.\u003cbr\u003e\n\u003cbr\u003e\n • \u003cstrong\u003eElimination of contamination risks\u003c\/strong\u003e\u003cbr\u003e\n By not handling or transferring infected instruments and materials, the risks are eliminated, because the processes are automated, with predetermined sequences that avoid the presence of the operator.\u003cbr\u003e\n\u003cbr\u003e\n • \u003cstrong\u003eSave time\u003c\/strong\u003e\u003cbr\u003e\r \nCurrently, all or part of the phases of the sterilization cycle are carried out manually, which makes the execution of protocols time-consuming. With the MultiSteril Fast, each phase is automated and cycle times are reduced by half.\u003cbr\u003e\n\u003cbr\u003e\n • \u003cstrong\u003eSignificant savings\u003c\/strong\u003e\u003cbr\u003e\n The entire process excludes the continuous presence of an operator, the management of the liquids used is automatic, no cleaning and disinfection at the end of the cycle, which represents a considerable reduction in overall times and costs.\u003cbr\u003e\n\u003cbr\u003e\n • \u003cstrong\u003ePerfect management of all phases\u003c\/strong\u003e\u003cbr\u003e\n You can be absolutely sure that the protocol has been carried out correctly and with reproducible and continuous quality.\u003cbr\u003e\n\u003cbr\u003e\n • \u003cstrong\u003eProtocol management\u003c\/strong\u003e\u003cbr\u003e\r \nSterilization only takes place if the material preparation procedure is carried out correctly; otherwise, the entire process is in vain. Multisteril Fast performs the entire cycle perfectly.\u003c\/p\u003e\n\n\n\u003cp\u003e • \u003cstrong\u003eSpace saving\u003c\/strong\u003e\u003cbr\u003e\n Space is another important issue. Sterilization rooms are often small and rationalizing space plays an important role. Multisteril Fast reduces everything to 40 cm.\u003c\/p\u003e\n\n\n\u003cp\u003e • \u003cstrong\u003eTotal cost\u003c\/strong\u003e\u003cbr\u003e\n Cost is an important component that must be controlled.\u003cbr\u003e\n Multisteril Fast costs around 2 euros per cycle.\u003cbr\u003e\n\u003cbr\u003e\n \u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eFeatures :\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n • Dimensions (L x H x D): 415 x 415 x 450 mm\u003cbr\u003e\n • Height with lid open: 750 mm\u003cbr\u003e\n • Open color depth: 530 mm\u003cbr\u003e\n • Equipped with a pump to drain the water\u003cbr\u003e\n • Voltage: 230 V\u003cbr\u003e\n • Frequency: 50\/60 Hz\u003cbr\u003e\n • Max. power consumption: 1kW\u003cbr\u003e\n • Weight: 20kg\u003cbr\u003e\r \n• Operating temperature: +5°C - +30°C\u003c\/p\u003e\n\n","brand":"Tecno-Gaz","offers":[{"title":"Default Title","offer_id":49691062731071,"sku":"42.006","price":3790.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/74620.png?v=1725143687"},{"product_id":"autoclave-18-litres-classe-b-iclave-plus-nsk","title":"18 litre autoclave - Class B - iClave Plus - NSK","description":"\u003ch2\u003eNSK iClave Plus autoclave - 18 liters\u003c\/h2\u003e\n\n\n\u003ch3\u003e\n\n\u003cbr\u003e\n iClave Plus Autoclave Technology and Functionality:\u003c\/h3\u003e\n\n\n\u003cp\u003e • \u003cstrong\u003eUser-friendly and easy-to-read control panel:\u003c\/strong\u003e Thanks to its sophisticated design and excellent visibility, the control screen is simple to use and easy to maintain. It also displays different colors depending on the status , which improves visibility of the progress of sterilization cycles.\u003cbr\u003e\r \n• \u003cstrong\u003eA creative and efficient thermal system:\u003c\/strong\u003e An advanced heating system allowing excellent thermal conductivity. The innovative heating system proposed by NSK optimizes the high thermal conductivity of copper. The device surrounding the copper chamber is a specific heating system also used in satellites. It integrates an electrothermal material incorporated into the silicone in order to heat the entire chamber uniformly and without heat loss.\u003cbr\u003e\n • \u003cstrong\u003eSterilization cycle data recording:\u003c\/strong\u003e All sterilization cycles are recorded on a USB stick and no specific software is required to view and print the records of all cycles. The system records all important cycle parameters under a unique date and time reference.\u003cbr\u003e\r \n• \u003cstrong\u003eVacuum sterilization for all types of instruments:\u003c\/strong\u003e A vacuum pump removes air from the chamber and cavities of the handpiece before sterilization.\u003cbr\u003e\n • \u003cstrong\u003eAntibacterial filter for greater safety:\u003c\/strong\u003e During the drying phase, the ventilation of the iClave plus is carried out through an antibacterial filter, thus eliminating the possibility of new contamination.\u003cbr\u003e\n • \u003cstrong\u003e50% more capacity than conventional autoclaves:\u003c\/strong\u003e By maintaining stable and precise temperatures throughout the chamber and by continuously monitoring the surface temperature, the iClave plus can use its entire 18-litre volume. The iClave plus offers 50% more sterilisation space than a traditional stainless steel chamber of the same size and ensures greater safety by limiting instrument overload.\u003c\/p\u003e\n\n\n\u003ch3\u003e\n\n\u003cbr\u003e\r \nTechnical specifications of the iClave Plus autoclave:\u003c\/h3\u003e\n\n\n\u003cp\u003e • Dimensions: L 445 x D 532 x H 428 mm\u003cbr\u003e\n • Chamber dimensions: Ø240 x 384 mm\u003cbr\u003e\n • Chamber volume: 18 liters\u003cbr\u003e\n • Net weight: 55 kg\u003cbr\u003e\n • Maximum power consumption: 1,900 W\u003cbr\u003e\n • CE supply voltage: 23 0V - 50 Hz\u003cbr\u003e\n • Air expulsion system: Vacuum pump 1, 3, 4 vacuums\u003cbr\u003e\n • Maximum solid load: 4 kg\u003cbr\u003e\n • Porous max load: 1.5 kg\u003c\/p\u003e\n\n\n\u003ch3\u003e\n\n\u003cbr\u003e\n Sterilization programs:\u003c\/h3\u003e\n\n\n\u003cp\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e Bowie \u0026amp; Dick: 134°C \/ 3.5 min \/ 3 empty\u003cbr\u003e\n Vacuum test: 20 min\u003c\/p\u003e\n\n\n\u003cp\u003e * 1 small load: included hollow type A and B instruments (MAX 0.5 kgs)\u003c\/p\u003e\n\n","brand":"NSK","offers":[{"title":"Default Title","offer_id":49691130396991,"sku":"22.030","price":7528.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/83107.png?v=1725145712"},{"product_id":"sachets-de-sterilisation-my-medical","title":"Sterilization bags - My Medical","description":"\u003ch2\u003e Sterilization bags - My Medical\u003c\/h2\u003e\n\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e\u003cstrong\u003eGeneral characteristics:\u003cbr\u003e\u003c\/strong\u003e •\u003c\/span\u003e Sterilization bag for large pedicure instrument kit!\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e•\u003c\/span\u003e Box of 200 sachets.\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e•\u003c\/span\u003e Made in Italy\u003cbr\u003e \u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e•\u003c\/span\u003e Perfect sealing of the bag thanks to the two layers of adhesive on the flap.\u003cbr\u003e \u003cspan\u003e•\u003c\/span\u003e Format suitable for sterilizing pedicure instruments.\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e•\u003c\/span\u003e Integrated sterilization indicator.\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eInner measurement (\u003cmeta charset=\"utf-8\"\u003e Height x Length)\u003c\/strong\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e•\u003c\/span\u003e 60 x 100 mm: 3.6 cm\u003cmeta charset=\"utf-8\"\u003e x 6.6 cm\u003cbr\u003e \u003cspan\u003e\u003cmeta charset=\"utf-8\"\u003e• 90 x 165 mm: 6.5cm x 13cm\u003cbr\u003e\u003c\/span\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e•\u003c\/span\u003e 75 x 250 mm: 5cm x 21.5cm\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e•\u003c\/span\u003e 90 x 250 mm: 6.5cm x 22.3cm\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e•\u003c\/span\u003e 140 x 260 mm: 12cm x 21.9cm \u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\n\u003ch2\u003e\n\n\u003c!----\u003e\u003cbr\u003e\n\n\u003c\/h2\u003e\n\n\u003c!----\u003e","brand":"My Medical","offers":[{"title":"90 mm x 250 mm","offer_id":49711882666303,"sku":"11.004.04","price":8.2,"currency_code":"EUR","in_stock":true},{"title":"60 mm X 100 mm","offer_id":49711882633535,"sku":"11.004.01","price":4.2,"currency_code":"EUR","in_stock":true},{"title":"140 mm x 260 mm","offer_id":49711882699071,"sku":"11.004.05","price":12.7,"currency_code":"EUR","in_stock":true},{"title":"190 mm x 330 mm","offer_id":49711882731839,"sku":"11.004.06","price":16.7,"currency_code":"EUR","in_stock":true},{"title":"90 mm x 165 mm","offer_id":49711882764607,"sku":"11.004.03","price":6.9,"currency_code":"EUR","in_stock":true},{"title":"75 mm x 250 mm","offer_id":49711882797375,"sku":"11.004.02","price":8.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/Sachets-de-sterilisation-My-Medical-My-Medical-444284871.webp?v=1774362502"},{"product_id":"autoclave-sterihero-speed-5l-melag","title":"SteriHero Speed+ autoclave - 5L - Melag","description":"\u003ch2\u003eSteriHero Speed+ Autoclave - 5L\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\n\n\n\u003c\/h2\u003e\n\n\u003cp\u003e \u003cspan\u003e\u003cstrong\u003eThe world's fastest autoclave.\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e \u003cmeta charset=\"utf-8\"\u003eMELAG \u003cspan\u003eSteriHero\u003c\/span\u003e \u003cstrong\u003e\u003cspan\u003eSpeed+\u003c\/span\u003e\u003c\/strong\u003e \u003cspan\u003eis the latest innovation in medical sterilization, designed to provide a\u003c\/span\u003e \u003cstrong\u003e\u003cspan\u003efast and reliable solution\u003c\/span\u003e\u003c\/strong\u003e \u003cspan\u003e. This advanced autoclave stands out for its\u003c\/span\u003e \u003cstrong\u003e\u003cspan\u003eexceptional speed\u003c\/span\u003e\u003c\/strong\u003e \u003cspan\u003e(6.5 minutes, plus drying), allowing healthcare professionals to keep pace in intense work environments.\u003c\/span\u003e \u003cstrong\u003e\u003cspan\u003eIdeal for podiatry, pedicure, veterinary, tattoo and beauty studios\u003c\/span\u003e\u003c\/strong\u003e \u003cspan\u003e. 60% less space required. Its\u003c\/span\u003e \u003cstrong\u003e\u003cspan\u003esimplified user interface\u003c\/span\u003e\u003c\/strong\u003e \u003cspan\u003eensures hassle-free operation, while its\u003c\/span\u003e \u003cstrong\u003e\u003cspan\u003ecompact and efficient design\u003c\/span\u003e\u003c\/strong\u003e \u003cspan\u003emaximizes laboratory space. With the promise of German quality and reliability that characterizes MELAG.\u003c\/span\u003e \u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\n\n\u003cstrong\u003e\u003cspan\u003e\u003cbr\u003eHighlights:\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\n\n\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e• Exceptional speed\u003c\/span\u003e\u003c\/strong\u003e \u003cspan\u003e: The SteriHero Speed+ stands out for its speed in the sterilization process, allowing professionals to keep pace in intense work environments.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e \u003cstrong\u003e\u003cspan\u003e\u003cmeta charset=\"utf-8\"\u003e• Intuitive interface\u003c\/span\u003e\u003c\/strong\u003e \u003cspan\u003e: Its smart, easy-to-use touchscreen simplifies operation, ensuring a hassle-free experience.\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e •\u003c\/span\u003e \u003cstrong\u003eGerman Quality\u003c\/strong\u003e \u003cspan\u003e: Manufactured by MELAG, a brand known for its excellence in medical devices, the SteriHero Speed+ offers reliability and durability.\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e •\u003c\/span\u003e \u003cstrong\u003e\u003cspan\u003eCompact design\u003c\/span\u003e\u003c\/strong\u003e \u003cspan\u003e: Its efficient design maximizes laboratory space, which is especially valuable in space-constrained environments.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e \u003cmeta charset=\"utf-8\"\u003e• \u003cstrong\u003e\u003cspan\u003eSafety Guaranteed\u003c\/span\u003e\u003c\/strong\u003e \u003cspan\u003e: Complies with sterilization standards and ensures the safety of medical instruments.\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e •\u003c\/span\u003e \u003cstrong\u003eMelag responsiveness\u003c\/strong\u003e \u003cspan\u003e: 12 technicians spread throughout France for quality monitoring\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e • \u003cstrong\u003eUse the Prion cycle:\u003c\/strong\u003e 18 min program at 134°C\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\n\n\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e Technical data: \u003c\/h3\u003e\n\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv id=\"description\" class=\"col-xs-12 col-md-8\"\u003e\n\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e•\u003c\/span\u003e Device dimensions (W x H x D): 30 x 30 x 59 cm\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e•\u003c\/span\u003e Cauldron dimensions (W x H x D): 20.3 x 8 x 31 cm \/ Chamber volume 5 litres\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e•\u003c\/span\u003e Cauldron capacity: Max. textiles\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e•\u003c\/span\u003e Weight of the device: 28 kg\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e•\u003c\/span\u003e Power supply: 220 - 230 V, 50 - 60 Hz (2,100 watts)\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e•\u003c\/span\u003e Documentation interfaces: USB and Network\u003cbr\u003e • Warranty: 2 years\u003cb\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/b\u003e\n \u003cp\u003e\u003cspan\u003eExperience the perfect combination of speed, efficiency and German quality with the SteriHero Speed+. Trust the reliable performance of this Class B sterilizer and ensure optimal sterilization results for your practice or laboratory.\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eEfficient sterilization in record time:\u003c\/strong\u003e \u003cspan\u003eThe SteriHero Speed+ enables S and B class sterilization in just 6.5 to 15 minutes (plus drying) for up to 2 kg of instruments on two trays. This makes your workflow up to six times faster than with conventional autoclaves.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eTailor-made drying process:\u003c\/strong\u003e With the flexDRY system, you can individually adapt the drying time between 1 and 60 minutes to your load and work processes, so that your instruments are always optimally dried.\u003cbr\u003e\u003c\/span\u003e \u003cbr\u003e\u003cstrong\u003eIntuitive operating concept:\u003c\/strong\u003e The large, intelligent touch display enables easy control, selection and monitoring of programs. This makes operating the autoclave child's play.\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eIntelligent documentation at no extra cost:\u003c\/strong\u003e Program protocols are documented via USB and network interfaces or can be printed with the MELAprint 80.\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eSpace-saving installation:\u003c\/strong\u003e Thanks to the Plug \u0026amp; Play installation concept, the SteriHero Speed+ can be put into operation in the blink of an eye and requires 60% less space than conventional autoclaves.\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eEnvironmentally friendly and patient friendly:\u003c\/strong\u003e Power Save mode puts the heater and display into energy-saving mode between sterilization processes, ensuring excellent energy efficiency.\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eHighest quality and reliability:\u003c\/strong\u003e The SteriHero Speed+ is developed, produced and optimized in Berlin according to the highest quality standards. It offers you quality that has been proven thousands of times and that you can rely on.\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e \u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cdiv class=\"row\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv id=\"highlights\" class=\"col-xs-12 col-md-4\"\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cp\u003e\u003c\/p\u003e","brand":"Melag","offers":[{"title":"Default Title","offer_id":50268913959231,"sku":"302.001","price":2950.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/8_93b1c336-65ef-4735-86e2-8883ff4c05f9.webp?v=1737729581"},{"product_id":"bobine-de-papier-pour-autoclave-57x30mm-my-medical","title":"Autoclave Paper Roll - 57x30mm - My Medical","description":"\u003ch2\u003e Autoclave Paper Roll - 57x30mm - My Medical\u003c\/h2\u003e\n\n\u003cp\u003e \u003cstrong\u003eGeneral characteristics:\u003c\/strong\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e• Dimensions: 57x30 mm\u003cbr\u003e\u003c\/span\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e•\u003c\/span\u003e 15 mm chuck\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e","brand":"My Medical","offers":[{"title":"Default Title","offer_id":51327435833663,"sku":"11.018","price":4.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/BobinedepapierpourAutoclave-57x30mm-MyMedical.png?v=1757074244"},{"product_id":"autoclave-sterihero-23l-melag","title":"Autoclave SteriHero 23L - Melag","description":"\u003ch2\u003eAutoclave SteriHero Vet 23 - 23L - Melag\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cstyle\u003e\n    .btn-manuel {\n        background-color: purple;\n        color: white!important;\n        padding: 10px 20px;\n        font-size: 16px;\n        border: none;\n        border-radius: 5px;\n        cursor: pointer;\n        text-decoration: none;\n        display: inline-block;\n    }\n    .btn-manuel:hover {\n        background-color: darkviolet;\n    }\n\u003c\/style\u003e\n\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/2317\/8823\/files\/brochure_sterihero_vet_23.pdf?v=1761905882\" class=\"btn-manuel\" target=\"_blank\" rel=\"noopener\"\u003eBROCHURE STERIHERO 23\u003c\/a\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003eCe tout nouvel autoclave 23L autonome de classe B, conçu par Melag, répond à toutes les exigences des cabinets et cliniques vétérinaires.\u003cbr\u003ePuissant, rapide et fiable, il combine les plus hauts standards de stérilisation, une utilisation intuitive et la qualité allemande reconnue depuis plus de 75 ans.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eLes points forts :\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eStérilisation de classe B conforme à la norme EN 13060\u003c\/strong\u003e\u003cbr\u003eLa technologie de vide fractionné assure la stérilisation la plus sûre pour tous vos instruments, emballés ou non, quelle que soit leur complexité.\u003cbr\u003eSécurité et hygiène maximales pour vos patients duveteux.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003ePuissance et efficacité optimales\u003c\/strong\u003e\u003cbr\u003e• Jusqu’à \u003cstrong\u003e6 kg d’instruments\u003c\/strong\u003e répartis sur \u003cstrong\u003e5 plateaux extra-longs\u003c\/strong\u003e\u003cbr\u003e• Cycle rapide à partir de 16 minutes\u003cbr\u003e• Séchage sous vide performant pour des instruments immédiatement prêts à l’emploi\u003cbr\u003e\u003cbr\u003e\u003cstrong data-start=\"1389\" data-end=\"1417\"\u003eSimplicité d’utilisation\u003c\/strong\u003e\u003cbr data-start=\"1417\" data-end=\"1420\"\u003eGrand \u003cstrong data-start=\"1428\" data-end=\"1456\"\u003eécran tactile SmartTouch\u003c\/strong\u003e intuitif pour sélectionner, lancer et suivre les cycles en toute facilité.\u003cbr data-start=\"1531\" data-end=\"1534\"\u003e\u003cstrong data-start=\"1536\" data-end=\"1565\"\u003eDocumentation automatique\u003c\/strong\u003e via \u003cstrong data-start=\"1570\" data-end=\"1599\"\u003eUSB, réseau ou imprimante\u003c\/strong\u003e (selon configuration).\u003cbr\u003e\u003cbr\u003e\u003cstrong data-start=\"1628\" data-end=\"1652\"\u003eAutonome et pratique\u003c\/strong\u003e\u003cbr data-start=\"1652\" data-end=\"1655\"\u003eRéservoirs d’eau intégrés pour une \u003cstrong data-start=\"1692\" data-end=\"1731\"\u003einstallation rapide et indépendante\u003c\/strong\u003e.\u003cbr data-start=\"1732\" data-end=\"1735\"\u003eParfait pour les établissements souhaitant une solution compacte, performante et mobile.\u003cbr\u003e\u003cbr\u003e\u003cstrong data-start=\"1831\" data-end=\"1863\"\u003eFiabilité et qualité premium\u003c\/strong\u003e\u003cbr data-start=\"1863\" data-end=\"1866\"\u003eDéveloppé et fabriqué à \u003cstrong data-start=\"1892\" data-end=\"1902\"\u003eBerlin\u003c\/strong\u003e, le SteriHero Vet 23 répond aux \u003cstrong data-start=\"1935\" data-end=\"1977\"\u003eexigences de qualité les plus strictes\u003c\/strong\u003e.\u003cbr\u003e\u003cbr\u003e\u003cstrong data-start=\"2167\" data-end=\"2188\"\u003eAssistance locale\u003c\/strong\u003e\u003cbr data-start=\"2188\" data-end=\"2191\"\u003eProfitez d’un \u003cstrong data-start=\"2207\" data-end=\"2243\"\u003eservice client expert et réactif\u003c\/strong\u003e dans votre région, toujours prêt à vous accompagner.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCaractéristiques techniques : \u003cbr\u003e\u003c\/strong\u003e• Dimensions : (L) 47 x (H) 50 x (P) 64 cm \u003cbr\u003e• Poids : 49 kg\u003cbr\u003e• Quantité de charge : max 6 kg d'instruments et 2 kg de textiles \u003cbr\u003e• Instruments compatibles : Tous : emballés, non emballés, creux, poreux, solides\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv id=\"description\" class=\"col-xs-12 col-md-8\"\u003e\u003c\/div\u003e\n\u003cdiv id=\"highlights\" class=\"col-xs-12 col-md-4\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"width: 900px; display: block; margin: 0 auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/2317\/8823\/files\/Capture_d_ecran_2025-10-31_a_11.22.19.png?v=1761906145\" alt=\"Melag vet 23\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Melag","offers":[{"title":"Default Title","offer_id":51623713341759,"sku":"302.003","price":5970.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/Autoclave-SteriHero-23L-Melag-Melag-439678995.png?v=1764857812"},{"product_id":"autoclave-sterihero-podo-18-17l-melag","title":"Autoclave SteriHero Podo 18 - 17L - Melag","description":"\u003ch2\u003eAutoclave SteriHero Podo 18 - 17L - Melag\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cstyle\u003e\n    .btn-manuel {\n        background-color: purple;\n        color: white!important;\n        padding: 10px 20px;\n        font-size: 16px;\n        border: none;\n        border-radius: 5px;\n        cursor: pointer;\n        text-decoration: none;\n        display: inline-block;\n    }\n    .btn-manuel:hover {\n        background-color: darkviolet;\n    }\n\u003c\/style\u003e\n\u003ch2\u003e\u003ca class=\"btn-manuel\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/2317\/8823\/files\/BROCHURE_STERIHERO_18.pdf?v=1761899035\" target=\"_blank\" rel=\"noopener\"\u003eBROCHURE STERIHERO 18\u003c\/a\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003eCe nouvel autoclave autonome de classe B, conforme aux réglementations des dispositifs médicaux, est spécialement conçu pour la podologie, alliant technologie avancée, sécurité maximale et simplicité d’utilisation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCaractéristiques générales : \u003cbr\u003e\u003c\/strong\u003e• \u003cstrong\u003eStérilisation vapeur de classe B\u003c\/strong\u003e conforme à la norme EN 13060\u003cbr\u003e• \u003cstrong\u003eSécurité optimale\u003c\/strong\u003e grâce à la procédure de vide fractionné, pour tous types d’instruments (emballés, creux, poreux, solides)\u003cbr\u003e• \u003cstrong\u003eCapacité élevée\u003c\/strong\u003e : jusqu’à 5 kg sur 5 plateaux\u003cbr\u003e• \u003cstrong\u003eCycles rapides\u003c\/strong\u003e : stérilisation complète à partir de 13 minutes\u003cbr\u003e• Séchage sous vide efficace, instruments immédiatement prêts à l’emploi\u003cbr\u003e•\u003cstrong\u003e \u003c\/strong\u003e\u003cstrong\u003eInterface tactile SmartTouch\u003c\/strong\u003e intuitive pour un contrôle complet des programmes\u003cbr\u003e• \u003cstrong\u003eDocumentation des cycles\u003c\/strong\u003e via USB, réseau ou impression du journal\u003cbr\u003e• Autonome avec réservoirs d’eau intégrés\u003cbr\u003e• \u003cstrong\u003eFiabilité allemande\u003c\/strong\u003e : conception et fabrication à Berlin, respect des standards de qualité\u003cbr\u003eMELAG\u003cbr\u003e• \u003cstrong\u003ePreuve de stérilisation garantie\u003c\/strong\u003e grâce à la surveillance intégrée des processus\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAvantages : \u003cbr\u003e\u003c\/strong\u003e• Instruments secs, stériles et prêts à l’emploi en un temps record\u003cbr\u003e• Sécurité maximale pour vos patients\u003cbr\u003e• Compact et pratique : dimensions 47 x 50 x 64 cm, compatible avec plateau de table de 60 cm\u003cbr\u003e• Maintenance simple et assistance locale rapide\u003cbr\u003e• Qualité MELAG : robustesse et durabilité, conçue pour un usage intensif\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCaractéristiques techniques : \u003cbr\u003e\u003c\/strong\u003e• Dimensions : (L) 47 x (H) 50 x (P) 64 cm \u003cbr\u003e• Poids : 48 kg\u003cbr\u003e• Quantité de charge : max 5 kg d'instruments et 1,8 kg de textiles \u003cbr\u003e• Instruments compatibles : Tous : emballés, non emballés, creux, poreux, solides\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv id=\"description\" class=\"col-xs-12 col-md-8\"\u003e\u003c\/div\u003e\n\u003cdiv id=\"highlights\" class=\"col-xs-12 col-md-4\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"width: 900px; display: block; margin: 0 auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/2317\/8823\/files\/Capture_d_ecran_2025-10-31_a_09.42.49.png?v=1761900180\" alt=\"Découvrir les vêtements Healing Hands\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Melag","offers":[{"title":"Default Title","offer_id":51623713407295,"sku":"302.002","price":5470.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/Autoclave-SteriHero-Podo-18-17L-Melag-Melag-439671822.png?v=1764857863"},{"product_id":"systeme-de-demineralisation-demin30-iclave-nsk","title":"Système de déminéralisation DEMIN30 - iClave+ - NSK","description":"\u003ch2\u003eSystème de déminéralisation DEMIN30 - iClave+ - NSK\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eCaractéristiques principales :\u003cbr\u003e\u003c\/strong\u003e\u003cspan\u003e• Système automatique de traitement de l’eau pour iClave+ 18L\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e• \u003c\/span\u003eSystème pour la déminéralisation complète de l’eau.\u003cbr\u003e• \u003cstrong\u003eKit EN 1717\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e: comprend le kit de déminéralisation et 2 filtres résine.\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e• \u003c\/span\u003eConforme à la prévention du reflux d’eau selon la norme EN 1717.\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e• \u003c\/span\u003eLe filtre peut être positionné sur le plan de travail ou à l’intérieur de l’armoire de stérilisation. \u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e•\u003c\/span\u003e Filtre jusqu’à 580 litres* d’eau avec une seule cartouche (*Calculé sur la base d’une eau avec une conductivité de 250 μS\/cm)\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"NSK","offers":[{"title":"Default Title","offer_id":51661073383743,"sku":"22.037","price":293.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/LampeLEDLina17WL.65cmouL.100cm-LIDavecinterrupteursanscontact.png?v=1766143321"}],"url":"https:\/\/www.my-medical.pt\/en\/collections\/autoclaves-et-accessoires-pour-dentistes.oembed?page=3","provider":"My Médical","version":"1.0","type":"link"}